9 Temmuz 2018 Pazartesi

CHILLED SYSTEM

CHILLED  SYSTEM

Water cooled chillers: With water cooled chillers, the refrigerant is cooled with a shell and tube condenser that is part of the chiller package. The condenser water heat is then rejected to the cooling tower located outdoors.
Glycol cooled chillers: Glycol-cooled chillers look identical to the water-cooled chillers. With glycol-cooled chillers, heat removed from the returning chilled water is rejected to a glycol loop for transport to the outside atmosphere. The glycol flows via pipes to an outdoor-mounted device called a dry cooler also known as a fluid cooler. Heat is rejected to the outside atmosphere as fans force outdoor air through the warm glycol-filled coil in the dry cooler.
 Air cooled chillers: With air-cooled chillers, the heat of refrigerant is rejected to an air-cooled condenser that is typically integrated with the chiller. This type of chiller is known as a packaged chiller and can also be integrated into a cooling facility module. Air-cooled chillers are typically located outdoors.



www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

6 Temmuz 2018 Cuma

How is humidity controlled with an AC system?

How is humidity controlled with an AC system?
Humidity is becoming more of a concern to building operators and owners. High indoor humidity leads to mold and mildew growth inside the building. The are several methods of controlling indoor humidity. The simplest (and most expensive) method is to connect a humidistat to an electric heater. When the humidity inside the building rises above the humidistat set point, the heater is turned on. The additional heat causes the air conditioning system to run longer and remove more moisture.
A more efficient method of controlling humidity is to use the waste heat from the refrigeration cycle itself. Instead of rejecting the waste heat outdoors, the heat is directed inside when humidity control is required. One form of heat reclaim is called hot-gas reheat or “refrigerant desuperheating” where refrigerant is passed through a heat exchanger located downstream of the cooling coil. The hot high pressure vapor leaving the compressor passes through this heat exchanger prior to entering the condenser coil. This in turn heats the indoor air and again causes the AC system to run longer to meet the thermostat set point. Although more energy is used, this is much more efficient than turning on an electric heater. Another form of heat reclaim is called sub-cool reheat. This strategy takes the warm liquid refrigerant from the condenser and passes it through a heat exchanger located downstream of the cooling coil. Less heat is available using this method because the majority of the heat has already been rejected at the condenser. Since more energy is used to pump liquid (as opposed to a gas) through the heat exchanger it would appear that this method is less efficient than the hot-gas method, however, the liquid in the heat exchanger is sub-cooled in the cold supply air stream which increases the capacity of the air conditioner. Since more capacity is available, the AC units is able to meet the thermostat more quickly.
Heat pipe heat exchangers or run-around coils perform a similar function when humidity control is required. Two heat exchanger are placed in the air stream, one upstream of the cooling coil and the other downstream of the cooling coil. These heat exchangers are connected together with piping. A heat transfer fluid, whether it be water or refrigerant, is either pumped or gravity fed from one heat exchanger to the other. The heat exchanger down stream of the cooling coil (re-heat coil) cools the liquid medium inside the heat exchanger and heats the air passing over the heat exchanger. The cold liquid inside the heat exchanger is moved to the heat exchanger upstream of the cooling coil (pre-cool coil) where it pre-cools the air passing over the heat exchanger and warms the liquid passing through the heat exchanger. The affect of a heat pipe or run-around coil is to reduce the sensible heat capacity of the AC system. The latent capacity of the AC system increases if direct-expansion equipment is used or remains relatively constant if chilled water equipment is used. Since the sensible capacity of the AC system has been reduced, the system must run longer to meet the thermostat set point thereby removing more moisture.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

What does a condenser in an ac unit do?


What does a condenser in an ac unit do?

The condenser does just what the name says: in the condenser the hot gaseous refrigerant coming from the compressor is cooled which causes it to condense into a liquid. Compressing a gas makes it much hotter, enough hotter than the outside air on a hot day that it can transfer its heat to that hot outside air  which makes the hot air even hotter, and cools the high pressure gas enough to make it condense into a fairly warm liquid.
The pressurized liquid refrigerant flows to the evaporator, where it is sprayed through a small nozzle into the evaporator (which is kept at low pressure because the refrigerant pump is constantly sucking on this part of the AC unit.)
When the warm high pressure refrigerant liquid sprays into the low pressure evaporator, it - you guessed it - evaporates. This lowers it temperature a lot, to near or below 0 degrees C. The air you wish to cool is blown over the cold evaporator, and the refrigerant gas gets somewhat warmer.
The warm low pressure refrigerant gas is sucked up and compressed into the condenser. And once it has transferred that heat to the outside air, it condenses, and the cycle repeats.
www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Classification of Valves

Classification of Valves

Fluid control valves are classified in many ways. Following is the classification of valves.


Multi Turn and Quarter Turn Valves

Multi turn valves need many turns of actuator to bring closure member (disc) from fully open position to fully closed position. Examples of multi turn valves are gate valves, globe valves, needle valves, and diaphragm and pinch valves.
While quarter turn valves need only quarter ,0 to 900 degree, motion of closure member (disc) to bring it from full open position to full closed position.  Examples of quarter turn valves are butterfly valves, ball vales and plug valves etc. Quarter turn vales are quickopening valves.

Self actuated Valves

Self actuated valves don’t need actuator to operate them. These valves operate based on some property of fluid line like pressure or flow. Self actuated valves don’t need operator’s interference to control the fluid. Examples of self actuated valves are check valves and pressure relief valves or safety valves.

Linear Motion and Rotary Motion Valves

In linear motion valves, disc moves in linear or straight path to open, close or throttle the flow in valve. While in Rotary motion valves, disc rotates to open, close or throttle the flow. Examples of linear motion valves are gate valves, needle valves, globe valves, diaphragm valves and pinch valves. Examples of Rotary motion valves are ball valves, butterfly valves etc.


General Types of valves

In general following are the types of valves.
• Gate valve
• Globe Valve
• Pinch Valve
• Needle valve
• Diaphragm valve
• Ball valve
• Butterfly Valve
• Check valve
• Pressure relief Valve (safety or relief valve)

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40



+90 553 343 50 40

Types of Heat Exchangers used in Hvac system

Types of Heat Exchangers used in Hvac system
Heat exchangers are essential part of any kind of HVAC system nowadays. Heat exchangers contribute substantially towards energy conservation and reduction in energy bills.So what are the different types of heat exchangers that a HVAC system can use? 
The main function of a heat recovery system is to increase the energy efficiency by reducing energy consumption and also by reducing the cost of operating by transferring heat between two gases or fluids, thus reducing the energy bills.
The heat exchangers are the best known devices for this purpose. In heat exchangers, as the name suggests, there is a transfer of energy from one fluid to another. Both these fluids are physically separated and there is no direct contact between the fluids. There are different types of heat exchangers such as shell and tube, U tube, shell and coil, helical, plate etc. The transfer of heat can be between steam and water, water and steam, refrigerant and water, refrigerant and air, water and water. Now let’s take a look as to what are the different types of heat exchangers.

Rotary wheel type heat exchanger
A rotary wheel type heat exchanger has a large surface cylinder which is attached to the shaft. It has got a gas permeable material inside it. When the cylinder rotates, both the gases move in a counter flow pattern axially to the shaft. The heat from the warm gas is absorbed by the gas permeable material and then it is transferred to the colder gas. Sometimes hygroscopic material is put on the gas permeable material to absorb the moisture from the gases. Thus the moist gas becomes dry and transfers the moisture to the dry gas. Both latent and sensible heat is transferred in this system.
Fixed Plate heat exchangers
These types of heat exchangers do not have any moving parts. They have fixed plates that are alternately arranged and are separate from each other. Both the gases and fluids flow separately in these alternate plates and the transfer of heat takes place between them. The flow can be counter flow, parallel flow or cross flow.
Heat pipe exchangers.
This type of heat exchanger has an evaporator and a condenser separated by a plate. It has tubes running parallel and separated from each other. On the evaporator side the hot air transfers its energy to the liquid refrigerant and thus boiling it. The vapor refrigerant now passes through the pipes to the condenser side. The opposite process takes place. The cold air now passes over the vapor refrigerant. The vapor refrigerant after transferring its energy turns to liquid and flows though the pipes to the evaporator side. This type of heat exchanger generally uses parallel flow patterns.
Run- around system
In this type of system, a pump circulates water or any other liquid through the system. There are coils that are mounted in either series or parallel to facilitate maximum amount of heat transfer. This type of system is beneficial in any season. This means that if the outside air is warmer than the exhaust air, the exhaust air pre cools outside air. And if the outside air is cooler than the exhaust air, the exhaust air pre heats the outside air, making the system more and more energy efficient.
Hot gas heat exchanger
The HVAC system’s compressor generates heat by compressing refrigerant. This heat can be captured and used for heating domestic water. For this purpose a heat exchanger is placed in between the compressor and the condenser. The water that is to be heated is circulated though this heat exchanger with the help of a pump whenever the HVAC system is on.
Double bundle condenser heat exchanger
This heat exchanger consists of two sets of water tubes in the condenser shell. The superheated gas is forced into the shell where the transfer of heat to the water takes place through the tubes.
Heat jackets
Water jackets are kept at the sides of a reciprocating engine or a gas turbine to absorb the heat generated. This heat can be used for generating steam or for heating water or fuel oil.
Hot flue gas heat exchangers
The hot flue gases from the boiler exhaust can be used to heat water or fuel oil. An arrangement consisting of a series of pipes or water jackets are made in the boiler exhaust for the transfer of the heat. It can mainly be used to preheat the boiler feed water.
Hot drain heat exchangers
Heat from the hot condensate used in the kitchen, bathrooms or laundry system can be used for boiling water.Condensate is continuously formed when the release of heat takes place. A heat exchanger placed in the condensate return can take the condensate heat for heating water.
Heat pump water heater
The atmosphere of kitchens and laundries is extremely hot. This heat can be used to heat water or for other purposes. This can be done by using a dedicated heat pump that mechanically concentrates the heat in the atmosphere and bring it to the temperature where it can be used.
www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

5 Temmuz 2018 Perşembe

Heating systems

Heating systems

Heating systems can take a couple of different forms. Some are furnaces that burn material to provide heated air through the ductwork, while another popular choice is boilers that heat water for steam radiators, or forced-water systems with baseboard radiators, electric heat, and heat pumps. A furnace will generally operate on natural gas or propane, while a boiler will use gas or oil to heat the water.

Another option is a radiant floor, also known as a hydronic heating system. These use piping under a floor, and are made up of flexible tubes that are filled with water or a glycol solution. These can heat any kind of floor, including concrete, and are an efficient method of providing warmth in a home. They can even be retrofitted into wooden flooring, though they need to be carefully installed in sheathing for wooden floors.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Dıffeent Types Of Hvac Systems

Dıffeent Types Of Hvac Systems

For most people, heating and cooling will account for as much as half of the energy they use. With this in mind, it’s important to choose a HVAC system that will meet your comfort needs, without drawing on excess power and escalating your cost of living.
• People living in hot or cold climates might go for a single stage system, designed to produce just heating or cooling. These tend to be inexpensive, but are also rather inefficient and will typically be working at capacity even when it’s not required.
• More advanced models will offer variable fan speeds to cut down on power use, however they remain inefficient when compared to multi-stage systems, and are thus more expensive to run over the long term.
• Zoned systems, on the other hand, have been designed to heat or cool individual parts of your home. This is done by designing zone valves and dampers inside the vents and ductwork that selectively block the flow of air. For people with larger properties this is of immeasurable value as it prevents the system from heating or cooling areas in the home that are not in use.
• HVAC systems can also be built to offer humidity control, and both humidifiers and dehumidifiers can be added as options to heating and cooling systems. People that live in very dry environments or the tropics find these additions to the system essential. With that being said, some people prefer to install separate humidifier or dehumidifier systems, so that they can manage the humidity of their environment without also having to turn on the air conditioner.



www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Heating, Ventilating, and Air Conditioning

Heating, Ventilating, and Air Conditioning
HVAC stands for Heating, Ventilating, and Air Conditioning, and HVAC systems are, effectively, everything from your air conditioner at home to the large systems used in industrial complexes and apartment blocks. A good HVAC system aims to provide thermal control and indoor comfort, and one that is designed using the principles of thermodynamics, fluid mechanics, and heat transfer.
The big air conditioner boxes that you might see on top of apartment blocks or offices are examples of (the visible part of) HVAC systems. They’re typically deployed in large industrial buildings, skyscrapers, apartment blocks, and large interior environments. They’re also an essential component of environments where there are health regulations requiring that temperature and humidity be kept at certain levels, using air taken from outside.
But heating and cooling systems you use in your home are also HVAC systems. They may take a different form, but many of the fundamental principles determining how they operate, as well as their efficiency, crosses over from the smallest of personal devices right through to the biggest commercial installations.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

How Aır Curtaıns Reduce Coolıng Costs


How Aır Curtaıns Reduce Coolıng Costs
Nearly all business owners are wary of costs and search for effective ways to save money. In warmer months, most businesses turn their thermostats down and make use of air conditioning systems. Maintaining an optimum temperature is essential for ensuring that customers enter the building- and that they wish to stay there.
However, controlling the climate of premises can be a costly affair. Air curtains can reduce cooling costs by preventing the amount of warm air that enters through an entryway. They will also prevent the loss of cooled air, by blocking the entry of hot air when a door is opened and closed. Both of these features mean that you can maintain a desired temperature, without needing to use air conditioning as often, or for as lengthy periods of time. This reduces the amount of energy used by air conditioning units, therefore saving your business valuable money spent on cooling costs. Air curtains also prevent outside contaminants- such as dust and insects – from entering an establishment. This can be invaluable for customers or employees with sensitivity to these contaminants, and can be particularly useful in months where hay fever is prominent.

Air curtains come in a variety models. Most are designed to fit above eight foot doorways; however, many companies have created models to fit in smaller or larger gaps. Air curtain length can also vary- some need only to be a little shorter than the width of the doorway, whereas other companies find that extra-long curtains, or several in a row, have a greater impact. You also choose the right strength to fit the requirements of your company. For example, air curtains made for walk-in freezers must work harder to account for the drastic difference in temperatures. Businesses that work in dusty or bug infested areas may look for air curtains that are best at filtering such contaminants.
Whatever your needs, air curtains are certain to save you money on the costs of climate control, and may even bring you a greater return as customers are happy to stay on site longer.
www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Types of Gas Burners

Types of Gas Burners
Types of residential gas burners include atmospheric injection, yellow (luminous) flame, and power burner units. Their classification is determined by the firing method used. Gas burners can also be divided into two broad classifications based on whether they are specifically designed as integral parts of gas-fired heating equipment, are used to convert a furnace or boiler from one fuel to another. The latter are called conversion burners and, at least outwardly, resemble the gun-type burners used in oil- fired appliances. Gas conversion burners are commonly designed and manufactured with integral controls so that they can be installed as a unit in the existing furnace or boiler.
Note
The burner(s) producing the heat in a gas-fired appliance is some- times called the main gas burner. Do not confuse the main gas burner with the pilot gas burner. The function of the latter (where it is used) is to light the gas flowing to the main gas burner.

Gas burners may also be classified as inshot and upshot types, depending on the design of the burner tube. The burner tube of an inshot gas burner is commonly a straight, adjustable venturi that extends horizontally from the unit. An upshot gas burner is characterized by a burner tube that extends horizontally from the unit and then bends to assume a vertical position.



www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Function of Condenser


Function of Condenser
In a cooling cycle of a refrigeration system, heat is absorbed by the vapor refrigerant in the evaporator followed by the compression of the refrigerant by the compressor. The high pressure and high temperature state of the vapor refrigerant is then converted to liquid at the cond. It is designed to condense effectively the compressed refrigerant vapor.
There are basically three types of condensing unit depending on how the heat is removed by the condensing medium which is usually water, air or a combination of both.
  • Air-Cooled types are usually used in the residential and small offices applications. They are used in small capacity systems below 20 tons. The advantages of using this design include not having to do water piping, not necessary to have water disposal system, saving in water costs and not much scaling problems caused by the mineral content of the water. It is also easier to install and has lower initial cost. There isn't much maintenance problems. The disadvantages are that it requires higher power per ton of refrigeration, has shorter compressor life and on days when most cooling is required, the least is available. 

  • The circulation of air-cooled type can be by natural convection or by forced convection (usually using blower or fan). Due to its limited capacity, natural convection is used in smaller applications such as freezers and refrigerators. In forced convection, air is circulated by using a fan or blower that pulls the atmospheric air through the finned coils. Internally, the refrigerant circulates through the coil and air flows across the outside of the tubes.
  • Water-Cooled There are 3 types commonly being used. They are shell and tube, shell and coil, and double tube. The most commonly used is the shell and tube type and are usually available from two tons up to couple of hundred tons. This design has lower power requirements per ton of refrigeration and the compressors can last longer compared to the air-cooled type. A water cooling tower is frequently used for higher capacity application.
  • Evaporative type which is a combination of water and air-cooled.
Air-Cooled and Water-Cooled Comparison Summary
  • Air-cooled type operates at higher head pressure or condensing pressure, hence reducing the capacity of the compressor and increases the power intake. In general, a 2 hp water-cooled system will require the same refrigeration as a 3 hp air-cooled system.
  • The maintenance costs of water-cooled type is about three to four times the air-cooled type. Air-cooled type maintenance is usually limited to regular lubrication of fan and motor bearings. Water-cooled type requires cleaning from algae and bacteria. Scales on the tubes are removed by using acid compound. Proper water treatment is also critical to the operation of the cond.
www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Filter Drier What is it and what does it do.

Filter Drier What is it and what does it do.
Filter driers are exactly what they sound like, they are filters. They filter the refrigerant inside the ac system. Filter driers need to be able to trap and contain moisture, acid, contaminants and wax from circulating throughout the air conditioner. Today's systems are very well designed, but problems can arise. HFC refrigerants by themselves will work for many years in a system, even when they are heated up above normal. However, under certain conditions HFC's can react and form acids. Moisture in the system can have a reaction with the refrigerants and cause hydrofluoric acid. These acids unchecked can cause havoc on your air conditioning system. Over time, pumping acid through the system will burn the insulation off the wires in the compressor. Once the wires have no more insulation, they will ark with the metal inside the compressor causing tripped breakers. We call this a grounded compressor and the only repair is a new one (very expensive). Another problem is the acid inside your air conditioner can eat away at every part or surface in the system, decomposing any surface. Over time, small pieces of parts can break free. These tiny pieces can circulate through the system, clogging capillary tubes, TXVs, or even the filter drier.

                A filter drier needs to be replaced anytime the air conditioners refrigeration system is worked on. When you replace a compressor, a TXV or any time the system is open to the atmosphere, change the filter. One way to tell if the filter is clogged is to take the temperature an inch before and an inch after the filter. If you have, more than a 3 degree F drop it has clogged and needs replaced. When in doubt change it out. Filter driers are lifesavers in some cases such as a compressor burnout. A compressor burnout is when the compressor becomes grounded and when it arks it actually burns the refrigerant. Burnt refrigerant usually will turn a darker color than normal sometimes black and may become wax like in extreme conditions. Just changing your AC compressor will not cut it. The only way to ensure the new compressor runs its full life is to install new filter driers and use acid away in the system. Acid away is a product used to remove acid from dirty systems. Some manufacturers say that a suction line filter drier does a better job of removing moisture from the system. That is because the moisture tends to condense in the cold suction line and is easily trapped by the suction line filter drier. However, a suction line drier is only used for clean up purposes, say after a burnout. Suction driers installed should be left for two days to remove moisture, wax, acid and small contaminants. A suction drier should never under any circumstances be left in a system for more than 3 days. As it will become restricted very fast. Yes, filter driers will cost you more to install. However, the price of not having one could be you buying a completely new system.
www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

4 Temmuz 2018 Çarşamba

Types of Filter

Types of Filter
There are basically two types in used today.
• Liquid Line Type
• Suction Line Type

Liquid Line Type is placed after the condenser coil and before the expansion valve. The liquid refrigerant that flows from the condenser to the expansion valve is filtered from particles and moisture before entering it. Good filter will filter out particles that are 20 micron or above from the system.
Some higher end device has sight glass that enables the technician to look into it to see the level of refrigerant. Some have chemical in it that indicate the amount of moisture in the system based on the color of it.
Suction Line Type is placed after the evaporator and before the compressor. This device is used to protect the compressor especially after any failure that contaminates the system.
Motor failure in the compressor usually cause acid and other contaminants to be introduced into the refrigerant system hence it is important to have the suction line filter dryer installed.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Expansion Valve


Expansion Valve
The expansion valve removes pressure from the liquid refrigerant to allow expansion or change of state from a liquid to a vapor in the evaporator.
The high-pressure liquid refrigerant entering the expansion valve is quite warm. This may be verified by feeling the liquid line at its connection to the expansion valve. The liquid refrigerant leaving the expansion valve is quite cold. The orifice within the valve does not remove heat, but only reduces pres­sure. Heat molecules contained in the liquid refrigerant are thus allowed to spread as the refrigerant moves out of the orifice. Under a greatly reduced pressure the liquid refrigerant is at its coldest as it leaves the expansion valve and enters the evaporator.
Pressures at the inlet and outlet of the expansion valve will closely approximate gauge pressures at the inlet and outlet of the compressor in most systems. The similarity of pressures is caused by the closeness of the components to each other. The slight variation in pressure readings of a very few pounds is due to resistance, causing a pressure drop in the lines and coils of the evaporator and condenser.

Two types of valves are used on machine air conditioning systems:
  • Internally-equalized valve - most common
  • Externally-equalized valve special control
Internally-Equalized Expansion Valve
The refrigerant enters the inlet and screen as a high-pressure liquid. The refrigerant flow is restricted by a metered orifice through which it must pass.
As the refrigerant passes through this orifice, it changes from a high-pressure liquid to a low-pressure liquid (or passes from the high side to the low side of the system).
Let's review briefly what happens to the refrigerant as we change its pressure.
As a high-pressure liquid, the boiling point of the refrigerant has been raised in direct proportion to its pressure. This has concentrated its heat content into a small area, raising the temperature of the refrigerant higher than that of the air passing over the condenser. This heat will then transfer from the warmer refrigerant to the cooler air, which con­denses the refrigerant to a liquid.
The heat transferred into the air is called latent heat of condensation. Four pounds (1.8 kg) of refrigerant flowing per minute through the orifice will result in 12,000 Btu (12.7 MJ) per hour transferred, which is designated a one ton unit. Six pounds (2.7 kg) of flow per minute will result in 18,000 Btu (19.0 MJ) per hour, or a one and one-half ton unit.
Let's look at each valve in detail.
The refrigerant flow through the metered orifice is extreamly important, anything restricting the flow will affect the entire system.
  • If the area cooled by the evaporator suddenly gets colder, the heat transfer requirements change. If the expansion valve continued to feed the same amount of refrigerant to the evaporator, the fins and coils would get colder until they eventually freeze over with ice and the air flow is stopped.
  • A thermal bulb has a small line filled with C02 is attached to the evaporator tailpipe. If the temperature on the tail pipe raises, the gas will expand and cause pressure against the diaphram. This expansion will then move the seat away from the orifice, allowing an increased refrigerant flow. As the tail pipe temperature drops, the pressure in the thermal bulb also drops, allowing the valve to restrict flow as required by the evaporator.
  • The pressure of the refrigerant entering the evaporator is fed back to the underside of the diaphragm through the internal equalizing passage. Expansion of the gas in the thermal bulb must overcome the internal balancing pressure before the valve will open to increase refrigerant flow.
  • A spring is installed against the valve and adjusted to a predetermined setting at the time of manufac­ture. This is the superheat spring which prevents slugging of the evaporator with excessive liquid.
  • Superheat is an increase in temperature of the gaseous refrigerant above the temperature at which the refrigerant vaporizes. The expansion valve is designed so that the temperature of the refrigerant at the evaporator outlet must have 8 to 12°F (4 to 7°C) of superheat before more refrigerant is allowed to enter the evaporator.
  • The adjusted tension of this spring is the determining factor in the opening and closing of the expansion valve. During opening or closing, the spring tension retards or assists valve operation as required. 
    • Normally, this spring is never adjusted in the field. Tension is adjusted from four to sixteen degrees as required for the unit on which it is to be installed. This original setting is sufficient for the life of the valve, and special equipment is required in most cases to accurately calibrate this adjustment
Externally-Equalized Expansion Valve
Operation of the externally-equalized valve is the same as the internal type except that evaporator pressure is fed against the underside of the diaphragm from the tail pipe of the evaporator by an equalizer line. This balances the temperature of the tail pipe through the expansion valve thermal bulb against the evaporator pressure taken from the tail pipe.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Expansion Valves


Expansion Valves
Expansion valves are devices used to control the refrigerant flow in a refrigeration system. They help to facilitate the change of higher pressure of liquid refrigerant in the condensing unit to lower pressure gas refrigerant in the evaporator.
The term "low side" is used to indicate the part of the system that operates under low pressure, in this case the evaporator. The "high side" is used to indicate the part of the system that operates under high pressure, in this case the condenser.
Types of Expansion Valves
There are basically four types of valves that are in used. These valves are also refer to as metering devices.
  • Automatic Exp. Valves
  • Thermostatic Exp. Valves
  • Capillary Tubes
  • Float Valves
Automatic Expansion Valve regulates the flow of refrigerant from the liquid line to the evaporator by using a pressure-actuated diaphragm. It maintains a constant pressure in the evaporator.
The setback is that it is not efficient if the load fluctuates hence this type is not suitable for use in air conditioning as the load fluctuates a lot during its operation.
Thermostatic Expansion Valve uses a valve mechanism to control the flow of liquid refrigerant into the evaporator coil. The flow is controlled by the pressure in the evaporator.
This type of metering device is able to operate well when the load fluctuates and hence is suitable for use in air conditioning system. When the evaporator warms, the valve provides a higher flow rate amd when it cools, it reduces the flow rate.
It is also commonly refer to as TXV, TEV or TX valve. There is a sensing bulb which detects the temperature of the coil and is usually located at a higher temperature within the evaporator.
The bulb must be clamped firmly to the coil to ensure proper sensing. When the temperature of the evaporator increases due to the demand for cooling, the pressure in the bulb will also increase hence pushing the spring to open the valve.
Similarly, when the temperature of the evaporator reduces due to a lack of demand for cooling, the pressure in the bulb will drop hence causing the spring to close the valve.
Capillary Tube is a tube with small internal diameter and could be coiled for part of its length. It is installed to the suction line. A filter-drier is sometimes fitted before the tube to remove dirt or moisture from the refrigerant.
This device is simple, does not have any moving part and lasts longer. In order to use this device, the amount of refrigerant in the system must be properly calibrated at factory level.

Due to its lower cost compared to TXV, this metering device is used in units that are produced in large quantity such as room or window air conditioners.
Depending on the capacity design of the system, the capillary tube internal diameter that is commonly used range from 0.031" to 0.065" and the outer diameter from 0.083" to 0.130".

Float Valve is actuated by a float that is immersed in the liquid refrigerant. Both low-side float and high side-float are used to control the flow of liquid refrigerant.
The low-side float helps to maintain a constant level of liquid refrigerant in the evaporator. It opens when there is no liquid in the evap. and closes when there is liquid in the evap.

The high-side float is located at the high pressure side of the system and maintain a constant level of refrigerant in the condenser. When the compressor operates, the condensed refrigerant flows to the float chamber and opens the valve.
This causes the refrigerant to flow into the evaporator where it is stored. As the liquid level falls in the float chamber, the valve opening will close hence preventing the liquid from flowing to the evap.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Evoporator

Evoporator
The evaporator works the opposite of the condenser, here refrigerant liquid is converted to gas, absorbing heat from the air in the compartment.
When the liquid refrigerant reaches the evaporator its pressure has been reduced, dissipating its heat content and making it much cooler than the fan air flowing around it. This causes the refrigerant to absorb heat from the warm air and reach its low boiling point rapidly. The refrigerant then vaporizes, absorbing the maximum amount of heat.
This heat is then carried by the refrigerant from the evaporator as a low-pressure gas through a hose or line to the low side of the compressor, where the whole refrigeration cycle is repeated.
The evaporator removes heat from the area that is to be cooled. The desired temperature of cooling of the area will determine if refrigeration or air con¬ditioning is desired. For example, food preservation generally requires low refrigeration temperatures, ranging from 40°F (4°C) to below 0°F (-18°C).
A higher temperature is required for human comfort. A larger area is cooled, which requires that large volumes of air be passed through the evaporator coil for heat exchange. A blower becomes a necessary part of the evaporator in the air conditioning system. The blower fans must not only draw heat-laden air into the evaporator, but must also force this air over the evaporator fins and coils where it surrenders its heat to the refrigerant and then forces the cooled air out of the evaporator into the space being cooled.

Fan Speeds
Fan speed is essential to the evaporation process in the system. Heat exchange, as we explained under condenser operation, depends upon a temperature differential of the air and the refrigerant. The greater the differential, the greater the amount of heat exchanged between the air and the refrigerant. A high heat load, as is generally encountered when the system is turned on, will allow rapid heat transfer between the air and the cooler refrigerant.
A blower fan turned on to its highest speed will deliver the most air across the fins and coils for rapid evaporation.
For the coldest air temperature from the evaporator, operate the blower fan at the lowest speed so the heat will be absorbed by the refrigerant from the air
Problems of Flooded or Starved Evaporator Coils
Changing the state of the refrigerant in the evaporator coils is as important as the air flow over the coils. Liquid refrigerant supplied to the coils by the expansion valve expands to a vapor as it absorbs heat from the air. Some liquid refrigerant must be supplied throughout the total length of the evaporator coils for full capacity.
A starved evaporator coil is a condition in which not enough refrigerant has been supplied through the total coil length. Therefore, expansion of the refrigerant has not occurred through the whole coil length, resulting in poor coil operation and too-low heat exchange.
A flooded evaporator is the opposite of the starved coil. Too much refrigerant is passed through the evaporator coils, resulting in unexpanded liquid passing onto the suction line and into the compressor.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Copper Tubes


Copper Tubes
Copper tube is one of the components that is needed in air conditioning and refrigerant system. The tube is used as a path for the refrigerant to flow between system components and to contain it from escaping to the atmosphere. Sizing, installation layout and fittings must be done properly to ensure that the system runs efficiently.
During installation, it is of utmost importance that moisture, dirt and other contaminants are prevented from entering the system. These foreign particles will affect the performance of the system and may even cause damage to some of the components.
During the production of the copper tube, the inside of the tube has been cleaned and dried before being sealed at both ends to ensure that it remains that way. You must check to make sure that the refrigerant that is going to be used does not react with the copper. Ammonia refrigerant will react with copper hence it should not be used. Instead, the stainless steel tubing type will have to be used.

Types Of Tubing
There are basically two types of tube namely the hard-drawn and the soft type.

Hard-Drawn Copper
This type of tubing is rigid, hard and stiff. It is not easily bent and should not be bent. Fittings are used to obtain the configuration needed for the installation. The length commonly available is 10 feet or 20 feet. There are three standard weight with different wall thickness for each type. Type K has the thickest wall tubing followed by Type L and Type M. If you need a higher pressure tube, thicker type is to be used to ensure it can handle the pressure of the refrigerant. Type L outer diameters typically starts from 3/8 inch followed by 1/2 inch, 5/8 inch, 3/4 inch, 7/8 inch, 11⁄8 inch, 13⁄8 inch, 15⁄8 inch, 21⁄8 inch and 25⁄8 inch.

Soft Copper 
The soft copper is flexible and comes in rolls of 25 feet or 50 feet. The typical outer diameter ranges from 1/8 inch to 13⁄8 inch. Markings of ACR are done on the tubing to indicate that it is used for air conditioning and refrigeration purposes. During production, these parts are cleaned and dehydrated to remove the moisture from the tube. It is then filled with nitrogen gas before being capped.
Insulation & Pre-caution 
In order to prevent the refrigerant from absorbing unnecessary heat from the ambient, the copper tube is insulated between the evaporator and the compressor at the low pressure side of the system. Hence you will be able to see the insulation material being wrapped around the copper tubes for this purpose. It is also to prevent condensation from happening on the tubes.
When cutting the tubing to the required length, make sure that you use a proper tool such as the tube cutter.The burr on the inside of the tube that resulted from the cutting must be removed from the tube as these contaminants will affect the flow of refrigerant as well as affecting the performance of the system.
When bending is required, take note that only the soft copper type can be bent. Use a proper tube bending springs to prevent flatten or kink.
When soldering or brazing is required, make sure that you have being trained to do this and adhere strictly to the instructions of the manufacturers.
Wear eye protection when particles are being released in the air as a result of your action.
When you are doing annealing process where you heat up the tube and allow it to cool slowly, make sure that you use a flared flame over a distance of 1 feet at a time and not concentrating the heat on one location.
Ensure the work place is well ventilated especially when fumes is being emitted as a result of your work. Do not breathe in excessive gas and adhesive.