CHILLED SYSTEM

CHILLED  SYSTEM

Water cooled chillers: With water cooled chillers, the refrigerant is cooled with a shell and tube condenser that is part of the chiller package. The condenser water heat is then rejected to the cooling tower located outdoors.
Glycol cooled chillers: Glycol-cooled chillers look identical to the water-cooled chillers. With glycol-cooled chillers, heat removed from the returning chilled water is rejected to a glycol loop for transport to the outside atmosphere. The glycol flows via pipes to an outdoor-mounted device called a dry cooler also known as a fluid cooler. Heat is rejected to the outside atmosphere as fans force outdoor air through the warm glycol-filled coil in the dry cooler.
 Air cooled chillers: With air-cooled chillers, the heat of refrigerant is rejected to an air-cooled condenser that is typically integrated with the chiller. This type of chiller is known as a packaged chiller and can also be integrated into a cooling facility module. Air-cooled chillers are typically located outdoors.



www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

5 Temmuz 2018 Perşembe

How Aır Curtaıns Reduce Coolıng Costs


How Aır Curtaıns Reduce Coolıng Costs
Nearly all business owners are wary of costs and search for effective ways to save money. In warmer months, most businesses turn their thermostats down and make use of air conditioning systems. Maintaining an optimum temperature is essential for ensuring that customers enter the building- and that they wish to stay there.
However, controlling the climate of premises can be a costly affair. Air curtains can reduce cooling costs by preventing the amount of warm air that enters through an entryway. They will also prevent the loss of cooled air, by blocking the entry of hot air when a door is opened and closed. Both of these features mean that you can maintain a desired temperature, without needing to use air conditioning as often, or for as lengthy periods of time. This reduces the amount of energy used by air conditioning units, therefore saving your business valuable money spent on cooling costs. Air curtains also prevent outside contaminants- such as dust and insects – from entering an establishment. This can be invaluable for customers or employees with sensitivity to these contaminants, and can be particularly useful in months where hay fever is prominent.

Air curtains come in a variety models. Most are designed to fit above eight foot doorways; however, many companies have created models to fit in smaller or larger gaps. Air curtain length can also vary- some need only to be a little shorter than the width of the doorway, whereas other companies find that extra-long curtains, or several in a row, have a greater impact. You also choose the right strength to fit the requirements of your company. For example, air curtains made for walk-in freezers must work harder to account for the drastic difference in temperatures. Businesses that work in dusty or bug infested areas may look for air curtains that are best at filtering such contaminants.
Whatever your needs, air curtains are certain to save you money on the costs of climate control, and may even bring you a greater return as customers are happy to stay on site longer.
www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Function of Condenser


Function of Condenser
In a cooling cycle of a refrigeration system, heat is absorbed by the vapor refrigerant in the evaporator followed by the compression of the refrigerant by the compressor. The high pressure and high temperature state of the vapor refrigerant is then converted to liquid at the cond. It is designed to condense effectively the compressed refrigerant vapor.
There are basically three types of condensing unit depending on how the heat is removed by the condensing medium which is usually water, air or a combination of both.
  • Air-Cooled types are usually used in the residential and small offices applications. They are used in small capacity systems below 20 tons. The advantages of using this design include not having to do water piping, not necessary to have water disposal system, saving in water costs and not much scaling problems caused by the mineral content of the water. It is also easier to install and has lower initial cost. There isn't much maintenance problems. The disadvantages are that it requires higher power per ton of refrigeration, has shorter compressor life and on days when most cooling is required, the least is available. 

  • The circulation of air-cooled type can be by natural convection or by forced convection (usually using blower or fan). Due to its limited capacity, natural convection is used in smaller applications such as freezers and refrigerators. In forced convection, air is circulated by using a fan or blower that pulls the atmospheric air through the finned coils. Internally, the refrigerant circulates through the coil and air flows across the outside of the tubes.
  • Water-Cooled There are 3 types commonly being used. They are shell and tube, shell and coil, and double tube. The most commonly used is the shell and tube type and are usually available from two tons up to couple of hundred tons. This design has lower power requirements per ton of refrigeration and the compressors can last longer compared to the air-cooled type. A water cooling tower is frequently used for higher capacity application.
  • Evaporative type which is a combination of water and air-cooled.
Air-Cooled and Water-Cooled Comparison Summary
  • Air-cooled type operates at higher head pressure or condensing pressure, hence reducing the capacity of the compressor and increases the power intake. In general, a 2 hp water-cooled system will require the same refrigeration as a 3 hp air-cooled system.
  • The maintenance costs of water-cooled type is about three to four times the air-cooled type. Air-cooled type maintenance is usually limited to regular lubrication of fan and motor bearings. Water-cooled type requires cleaning from algae and bacteria. Scales on the tubes are removed by using acid compound. Proper water treatment is also critical to the operation of the cond.
www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

4 Temmuz 2018 Çarşamba

Expansion Valves


Expansion Valves
Expansion valves are devices used to control the refrigerant flow in a refrigeration system. They help to facilitate the change of higher pressure of liquid refrigerant in the condensing unit to lower pressure gas refrigerant in the evaporator.
The term "low side" is used to indicate the part of the system that operates under low pressure, in this case the evaporator. The "high side" is used to indicate the part of the system that operates under high pressure, in this case the condenser.
Types of Expansion Valves
There are basically four types of valves that are in used. These valves are also refer to as metering devices.
  • Automatic Exp. Valves
  • Thermostatic Exp. Valves
  • Capillary Tubes
  • Float Valves
Automatic Expansion Valve regulates the flow of refrigerant from the liquid line to the evaporator by using a pressure-actuated diaphragm. It maintains a constant pressure in the evaporator.
The setback is that it is not efficient if the load fluctuates hence this type is not suitable for use in air conditioning as the load fluctuates a lot during its operation.
Thermostatic Expansion Valve uses a valve mechanism to control the flow of liquid refrigerant into the evaporator coil. The flow is controlled by the pressure in the evaporator.
This type of metering device is able to operate well when the load fluctuates and hence is suitable for use in air conditioning system. When the evaporator warms, the valve provides a higher flow rate amd when it cools, it reduces the flow rate.
It is also commonly refer to as TXV, TEV or TX valve. There is a sensing bulb which detects the temperature of the coil and is usually located at a higher temperature within the evaporator.
The bulb must be clamped firmly to the coil to ensure proper sensing. When the temperature of the evaporator increases due to the demand for cooling, the pressure in the bulb will also increase hence pushing the spring to open the valve.
Similarly, when the temperature of the evaporator reduces due to a lack of demand for cooling, the pressure in the bulb will drop hence causing the spring to close the valve.
Capillary Tube is a tube with small internal diameter and could be coiled for part of its length. It is installed to the suction line. A filter-drier is sometimes fitted before the tube to remove dirt or moisture from the refrigerant.
This device is simple, does not have any moving part and lasts longer. In order to use this device, the amount of refrigerant in the system must be properly calibrated at factory level.

Due to its lower cost compared to TXV, this metering device is used in units that are produced in large quantity such as room or window air conditioners.
Depending on the capacity design of the system, the capillary tube internal diameter that is commonly used range from 0.031" to 0.065" and the outer diameter from 0.083" to 0.130".

Float Valve is actuated by a float that is immersed in the liquid refrigerant. Both low-side float and high side-float are used to control the flow of liquid refrigerant.
The low-side float helps to maintain a constant level of liquid refrigerant in the evaporator. It opens when there is no liquid in the evap. and closes when there is liquid in the evap.

The high-side float is located at the high pressure side of the system and maintain a constant level of refrigerant in the condenser. When the compressor operates, the condensed refrigerant flows to the float chamber and opens the valve.
This causes the refrigerant to flow into the evaporator where it is stored. As the liquid level falls in the float chamber, the valve opening will close hence preventing the liquid from flowing to the evap.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Evoporator

Evoporator
The evaporator works the opposite of the condenser, here refrigerant liquid is converted to gas, absorbing heat from the air in the compartment.
When the liquid refrigerant reaches the evaporator its pressure has been reduced, dissipating its heat content and making it much cooler than the fan air flowing around it. This causes the refrigerant to absorb heat from the warm air and reach its low boiling point rapidly. The refrigerant then vaporizes, absorbing the maximum amount of heat.
This heat is then carried by the refrigerant from the evaporator as a low-pressure gas through a hose or line to the low side of the compressor, where the whole refrigeration cycle is repeated.
The evaporator removes heat from the area that is to be cooled. The desired temperature of cooling of the area will determine if refrigeration or air con¬ditioning is desired. For example, food preservation generally requires low refrigeration temperatures, ranging from 40°F (4°C) to below 0°F (-18°C).
A higher temperature is required for human comfort. A larger area is cooled, which requires that large volumes of air be passed through the evaporator coil for heat exchange. A blower becomes a necessary part of the evaporator in the air conditioning system. The blower fans must not only draw heat-laden air into the evaporator, but must also force this air over the evaporator fins and coils where it surrenders its heat to the refrigerant and then forces the cooled air out of the evaporator into the space being cooled.

Fan Speeds
Fan speed is essential to the evaporation process in the system. Heat exchange, as we explained under condenser operation, depends upon a temperature differential of the air and the refrigerant. The greater the differential, the greater the amount of heat exchanged between the air and the refrigerant. A high heat load, as is generally encountered when the system is turned on, will allow rapid heat transfer between the air and the cooler refrigerant.
A blower fan turned on to its highest speed will deliver the most air across the fins and coils for rapid evaporation.
For the coldest air temperature from the evaporator, operate the blower fan at the lowest speed so the heat will be absorbed by the refrigerant from the air
Problems of Flooded or Starved Evaporator Coils
Changing the state of the refrigerant in the evaporator coils is as important as the air flow over the coils. Liquid refrigerant supplied to the coils by the expansion valve expands to a vapor as it absorbs heat from the air. Some liquid refrigerant must be supplied throughout the total length of the evaporator coils for full capacity.
A starved evaporator coil is a condition in which not enough refrigerant has been supplied through the total coil length. Therefore, expansion of the refrigerant has not occurred through the whole coil length, resulting in poor coil operation and too-low heat exchange.
A flooded evaporator is the opposite of the starved coil. Too much refrigerant is passed through the evaporator coils, resulting in unexpanded liquid passing onto the suction line and into the compressor.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Basic Types of Check Valves

Basic Types of Check Valves

It is very important for HVAC mechanical engineer to know about various valves being used in mechanical industry.Various check valve types have been developed to cater to the diversified requirements in piping systems in various applications.These various types of check valves offer many advantages and disadvantages .One type of check valve ideal for one applicationmay be misfit for another application.Plant engineers have to look into many factors to decide which type of valve would be they using in that particular application.


Following are the main check valve types used in various applications.

1. Swing Check Valve
2. Tilting Disk Check Valves
3. Lift Check Valves
4. Piston Check Valves
5. Butterfly Check Valves
6. Stop Check Valves
7. Other Check valve types (Ball check valve, diaphragm check valve etc)


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Why we use Check Valves or Non-Return Valves or one way valves?

Why we use Check Valves or Non-Return Valves or one way valves?

Sometimes reverse flow may be detrimental for equipment or process so it needs to be uni-directional for operational safety. This operational safety is accomplished by valve check. Valves check are self actuated and self operating devices.
• Check   Valves   are used to protect the equipment that can be affected by reverse flow, such as flow meters, strainers and flow control valves.
• Check   Valves   are used to check the pressure surges associated with hydraulic forces, for example, water hammer
• Check Valves   are used to prevent the flooding that can take place if flow reversed.
• Check Valves   are used to prevent the reverse flow on system shutdown.
• Check Valves   are used to to prevent the flow under gravity.
• Check Valves   are used for relief of vacuum conditions.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

What is a Check Valve or Non-return valve (NRV)?

What is a Check Valve or Non-return valve (NRV)?

Check valves or non-return valves are self actuated valves and designed to prevent the reversal of flow in a piping system. In other words we can say that Check valves are basically backflow preventers. Valve Check continues to work even if plant loses it power,air supply or hydraulic power source. Even these flow preventers or one way valves do not need operators assistance to function.

How Does  a Check valve Work?

Check valves are activated by the flowing material in the pipeline.This flowing material may be gas,water ,air ,oil or steam in pipeline. The pressure of the fluid passing through the system opens the check valve, while any reversal of flow will close the valve.Opening of valve is basically lifting or swinging of check valve disc thus allowing the flow in one direction.Closure in check valve, for backflow prevention, is accomplished by the weight of the check mechanism, by back pressure, by a spring, or by a combination of these means.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40



+90 553 343 50 40

AIR-CONDITIONING SYSTEMS

AIR-CONDITIONING SYSTEMS
The system by which air conditioners provide cooling is called the Refrigerant Cycle. This system has four major components common to all air-conditioning systems. These components and their basic functions are listed below.


1. Compressor
Refrigerant is drawn from the evaporator and pumped to the condenser by the compressor. The compressor also pressurizes the refrigerant vapor so that it will change state (condense) readily.
2. Condenser
The high-pressure refrigerant vapor releases heat through the condenser coils as it condenses into liquid refrigerant. making it easier to vaporize.
3. Metering Device
(capillary tube, txv valve) The metering device restricts the flow of liquid refrigerant from the condenser to the evaporator. As refrigerant passes through the metering device, its pressure decreases.
4. Evaporator
The low-pressure liquid refrigerant absorbs heat as it vaporizes in the evaporator coils.
The process described above is the Refrigerant System or Refrigerant Cycle. It is the system on which virtually all modern Air-Conditioning and refrigeration is based.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Basic Principles of Air Conditioning

Basic Principles of Air Conditioning
You don’t have to be an air-conditioning expert to use Bilkar Coolers, but understanding the basics of air conditioning will help you understand how Bilkar Coolers work.
This section highlights some of the basic principles of air conditioning for those who would benefit from additional knowledge in this area.
PRINCIPLES OF COOLING
Heat Transfer
Heat is a form of energy. Every object on earth has some heat energy. The less heat an object has, the colder we say it is. Cooling is the process of transferring heat from one object to another. When an air-conditioning system cools, it is actually removing heat and transferring it somewhere else. This can be demonstrated by turning on a Spot Cooler and placing one hand in front of the cold air nozzle and the other over the warm air exhaust. You will feel the action of the transfer of heat.
SENSIBLE AND LATENT HEAT
There are two forms of heat energy: sensible heat and latent heat.
Sensible heat is the form of heat energy which is most commonly understood because it is sensed by touch or measured directly with a thermometer. When weather reporters say it will be 90 degrees, they are referring to sensible heat.
Latent heat cannot be sensed by touch or measured with a thermometer. Latent heat causes an object to change its properties. For example, when enough latent heat is removed from water vapor (steam or humidity), it condenses into water (liquid).
If enough latent heat is removed from water (liquid), it will eventually freeze. This process is reversed when latent heat is added.

CHANGE OF STATE
An object that changes from a solid to a liquid or liquid to vapor is referred to as a change of state. When an object changes state, it transfers heat rapidly.
HUMIDITY
Moisture in the air is called humidity. The ability of air to hold moisture directly relates to its temperature.
The warmer air is, the more moisture it is capable of holding. Relative humidity is the percentage of moisture in the air compared to the amount of moisture it can hold. A moisture content of 70°F air with 50% relative humidity is lower than 80°F air with 50% relative humidity.
When the humidity is low, sweat evaporates from your body more quickly. This allows you to cool off faster. High humidity conditions do not allow sweat to evaporate as well because the air is at its maximum capacity.
Humidity is also a form of latent heat. When air contains more humidity, it has more latent heat.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

What Is Considered the Air Flow of an Axial Fan?

What Is Considered the Air Flow of an Axial Fan?
Airflow is measured in cubic meters per hour and describes the expected amount of air that will flow through the fan in one hour’s time. In complex systems, there may be many fans working together to get a desired airflow. Axial fans can also be installed in different locations and set up so that airflow is directed smoothly through a space, or so that the space has positive or negative pressure due to the working of the fans.


What Is the Fan Speed?
Fan speed is measured in rpms and describes the speed at which the propeller rotates. This is variable on many models fans and, in fact, the axial fans used in computers are designed to be variable speed to cut down on a nuisance factor of high rpms: noise.

Fan speeds tend to be directly related to fan size. Larger fans move more air and, because of that, they can oftentimes be run at lower rpms than smaller fans to move the same quantity of air. For applications where a user is going to be next to a machine that requires fan cooling, putting larger fans in the device sometimes allows for proper cooling with less noise than smaller fans would generate.

What Is Considered AC or DC Operation of an Axial Fan?
This simply indicates whether the fan runs on AC or DC power.

What Does the Direction of Curve Define?
The direction of the blades in relation to the rotation of the fan is described as the curve. In a forward curved fan, for instance, the blades are oriented in the same direction as the rotation of the fan. In some cases, very engineered systems may require a specific curve direction for the fan. This may not be much of a factor in less demanding applications, however.


What Is the Power Consumption of an Axial Fan?
The power consumption of an axial fan is one of its most desirable features. This describes the amount of power required to run the device in watts. Axial fans are enormously efficient to operate.

How Is the Noise level of an Axial Fan Defined?
All fans make some noise. This is measured in decibels (dB) and expresses the amount of noise the fan generates during normal operation. This is a concern where both large and small fans are being installed. Small fans rotating at high rpms can generate a great deal of noise, for instance, a problem for powerful computers that require a great degree of thermal management. Larger fans can also generate a great deal of noise, in some cases. Poorly engineered fans may have problems with vibration, which can increase the amount of noise they generate.

Which Sensor Output Types Exist for Axial Fans?
Sensor outputs on fans are important in applications where flow has to be precisely controlled, such as in computer cases. Fans are outfitted with many different types of sensors, including tachometers, voltage outputs, temperature outputs, open collectors, which provide rpm data.
Some fans can be very precisely controlled via software. Computer fans can usually have their speeds set manually by the user, which some programmers and other demanding users take advantage of to make sure their computer is being cooled as much as possible at all times.

Which Blade Diameters Are Available for Axial Fans?
Blade diameters range from a few millimetres and up. It is simply the diameter of the propeller element of the fan


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

3 Temmuz 2018 Salı

How Does an Axial Fan Function?

How Does an Axial Fan Function?
The name of an axial fan precisely describes its function. The fan blades rotate around the shaft, powered by the electric motor. The rotating blades function as a propeller. This creates airflow when the rotation of propeller lowers the air pressure behind it, sucking the air into the propeller parallel to the shaft.
In terms of human comfort, this creates a wind chillthat can make a room seem cooler on hot days.  Fans can also be used to direct heated or cooled air into a room.

For machinery, they offer a precise way to direct airflow onto or around parts that need to be cooled. Axial fans can also be used to influence the pressure in an environment. This is clearly demonstrated in cooling systems for computer cases. Some builders will set up the fans so that air is being sucked in from the outside faster than it’s being discharged from the inside, resulting in positive pressure. Other builders will try to evacuate as much air from the case as possible, resulting in negative pressure.
In a household and in industrial settings the working of an axial fan can be very dramatic. Whole house fans, for instance, are cooling solutions for homes that are much more efficient than air conditioning and that work by creating a continuous airflow through the entire house, cooling it off very effectively.
Axial fans can suffer diminished performance from stalling and surging. Stalling occurs as an interruption in the flow of air across the fan. Surging is just the opposite. In complex ventilation systems, fans have to be set up in a way that ensures that they don’t cause stalling problems.
Poorly built fans may be subject to issues with vibration, which could have significant consequences if the fans are installed on sensitive equipment.
www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

What Is an Axial Fan?

What Is an Axial Fan?
An axial fan is a type of mechanical fan. Its name describes the direction that fluids flow through it.
These designs will be familiar to most people as box fans, computer case fans, window fans and many other types. These fans create airflow that runs parallels to the rotating shaft on the fan. They are highly controllable, and not only the speed of the fan but the direction of the flow can be precisely directed. They are heavily used in industry and the size range available is significant. They range from very small fans, some of which are designed so that a person can hold them in their hand for personal cooling, to enormous fans used in industrial facilities and for scientific purposes.
Axial fans have several advantages that make them desirable compared to other options, such as centrifugal fans, for certain applications. For the amount of fluid they move, for instance, they are very quiet. A centrifugal fan may actually provide better cooling in a computer case, for example, but the increased noise would likely outweigh any benefits. Axial fans can also be added to cases with minimal modifications, while other options—including water-cooling systems—are bulky and expensive.

This combination of good performance, long lifespan and affordability makes axial fans very common in many areas of life. Households commonly have more than one, as they provide an excellent solution to heating and cooling needs, allowing refrigerated, evaporative cooled or heated air to be directed around a house for temperature management. They also allow air from windows and air inside the house to be moved without being cooled or heated, providing an economical alternative to air conditioning in hot areas.
Axial fans are used heavily in industry, where very large floor fans, duct fans or exhaust fans may be largely responsible for maintaining the interior air quality of a facility. This makes them vital equipment for factories, warehouses and other large spaces where air needs to be circulated. Some of the fans used in these applications are very large, designed to keep air flowing through extensive ducting systems or circulate a huge volume of air.
The electric motors that drive axial fans can be controlled easily, allowing higher and lower rpms to be selected, direction of flow to be changed and other variables to be changed, providing a significant degree of control.
www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

PASSIVE COOLING

PASSIVE COOLING
Some people go to the extreme and get rid of their AC units entirely. Passive cooling is the greenest of trends and a great way to save money. Passive cooling revolves around the concept of removing warm air from your home using the interaction between the house and its surroundings. There are several ways to block and remove heat, including shading through landscaping, using a dark exterior paint, installing a radiant barrier in the roof rafters and good old- fashioned insulation. Another way is through thermal siphoning, the process of removing heat through controlled airflow. Opening the lower windows on the breezy side of your house and the upper windows on the opposite side creates a vacuum that draws out the hot air. Ceiling fans and roof vents are other ways to direct heat out at low cost


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Energy Efficient Cooling Systems

Energy Efficient Cooling Systems
Because of the rising costs of electricity and a growing trend to "go green," more people are turning to alternative cooling methods to spare their pocketbooks and the environment. Big businesses are even jumping on board in an effort to improve their public image and lower their overhead.
Ice cooling systems are one way that businesses are combating high electricity costs during the summer. Ice cooling is as simple as it sounds. Large tanks of water freeze into ice at night, when energy demands are lower. The next day, a system much like a conventional air conditioner pumps the cool air from the ice into the building. Ice cooling saves money, cuts pollution, eases the strain on the power grid and can be used alongside traditional systems. The downside of ice cooling is that the systems are expensive to install and require a lot of space. Even with the high startup costs, more than 3,000 systems are in use worldwide
An ice cooling system is a great way to save money and conserve energy, but its price tag and space requirements limit it to large buildings. One way that homeowners can save on energy costs is by installing geo-thermal heating and cooling systems, also known as ground source heat pumps (GSHP). The Environmental Protection Agency recently named geo-thermal units "the most energy-efficient and environmentally sensitive of all space conditioning systems"
Although it varies, at six feet underground the Earth's temperatures range from 45 to 75 degrees Fahrenheit. The basic principle behind geo-thermal cooling is to use this constant temperature as a heat source instead of generating heat with electricity.

The most common type of geo-thermal unit for homes is the closed-loop system. Polyethylene pipes are buried under the ground, either vertically like a well or horizontally in three- to six-foot trenches. They can also be buried under ponds. Water or an anti-freeze/water mixture is pumped through the pipes. During the winter, the fluid collects heat from the earth and carries it through the system and into the building. During the summer, the system reverses itself to cool the building by pulling heat from the building, carrying it through the system and placing it in the ground
Homeowners can save 30 to 50 percent on their cooling bills by replacing their traditional HVAC systems with ground source heat pumps. The initial costs can be up to 30 percent more, but that money can be recouped in three to five years, and most states offer financial purchase incentives. Another benefit is that the system lasts longer than traditional units because it's protected from the elements and immune to theft


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Chilled-water and Cooling-tower AC Units

Chilled-water and Cooling-tower AC Units

Although standard air conditioners are very popular, they can use a lot of energy and generate quite a bit of heat. For large installations like office buildings, air handling and conditioning is sometimes managed a little differently.
Some systems use water as part of the cooling process. The two most well-known are chilled water systems and cooling tower air conditioners.
·         Chilled water systems - In a chilled-water system, the entire air conditioner is installed on the roof or behind the building. It cools water to between 40 and 45 degrees Fahrenheit (4.4 and 7.2 degrees Celsius). The chilled water is then piped throughout the building and connected to air handlers. This can be a versatile system where the water pipes work like the evaporator coils in a standard air conditioner. If it's well-insulated, there's no practical distance limitation to the length of a chilled-water pipe.
·         Cooling tower technology - In all of the air conditioning systems we've described so far, air is used to dissipate heat from the compressor coils. In some large systems, a cooling tower is used instead. The tower creates a stream of cold water that runs through a heat exchanger, cooling the hot condenser coils. The tower blows air through a stream of water causing some of it to evaporate, and the evaporation cools the water stream. One of the disadvantages of this type of system is that water has to be added regularly to make up for liquid lost through evaporation. The actual amount of cooling that an air conditioning system gets from a cooling tower depends on the relative humidity of the air and the barometric pressure.

Because of rising electrical costs and environmental concerns, some other air cooling methods are being explored, too. One is off-peak or ice-cooling technology. An off-peak cooling system uses ice frozen during the evening hours to chill interior air during the hottest part of the day. Although the system does use energy, the largest energy drain is when community demand for power is at its lowest. Energy is less expensive during off-peak hours, and the lowered consumption during peak times eases the demand on the power grid.
Another option is geo-thermal heating. It varies, but at around 6 feet (1.8 meters) underground, the earth's temperature ranges from 45 to 75 degrees Fahrenheit (7.2 to 23.8 degrees Celsius). The basic idea behind geo-thermal cooling is to use this constant temperature as a heat or cold source instead of using electricity to generate heat or cold. The most common type of geo-thermal unit for the home is a closed-loop system. Polyethylene pipes filled with a liquid mixture are buried underground. During the winter, the fluid collects heat from the earth and carries it through the system and into the building. During the summer, the system reverses itself to cool the building by pulling heat through the pipes to deposit it underground 
For real energy efficiency, solar powered air conditioners are also making their debut. There may still be some kinks to work out, but around 5 percent of all electricity consumed in the U.S. is used to power air conditioning of one type or another, so there's a big market for energy-friendly air conditioning options 

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Window and Split-system AC Units


Window and Split-system AC Units

A window air conditioner unit implements a complete air conditioner in a small space. The units are made small enough to fit into a standard window frame. You close the window down on the unit, plug it in and turn it on to get cool air. If you take the cover off of an unplugged window unit, you'll find that it contains:
·         A compressor
·         An expansion valve
·         A hot coil (on the outside)
·         A chilled coil (on the inside)
·         Two fans
·         A control unit
The fans blow air over the coils to improve their ability to dissipate heat (to the outside air) and cold (to the room being cooled).
When you get into larger air-conditioning applications, its time to start looking at split-system units. A split-system air conditioner splits the hot side from the cold side of the system, as in the diagram below.
The cold side, consisting of the expansion valve and the cold coil, is generally placed into a furnace or some other air handler. The air handler blows air through the coil and routes the air throughout the building using a series of ducts. The hot side, known as the condensing unit, lives outside the building.
The unit consists of a long, spiral coil shaped like a cylinder. Inside the coil is a fan, to blow air through the coil, along with a weather-resistant compressor and some control logic. This approach has evolved over the years because it's low-cost, and also because it normally results in reduced noise inside the house (at the expense of increased noise outside the house). Other than the fact that the hot and cold sides are split apart and the capacity is higher (making the coils and compressor larger), there's no difference between a split-system and a window air conditioner.

In warehouses, large business offices, malls, big department stores and other sizeable buildings, the condensing unit normally lives on the roof and can be quite massive. Alternatively, there may be many smaller units on the roof, each attached inside to a small air handler that cools a specific zone in the building.
In larger buildings and particularly in multi-story buildings, the split-system approach begins to run into problems. Either running the pipe between the condenser and the air handler exceeds distance limitations (runs that are too long start to cause lubrication difficulties in the compressor), or the amount of duct work and the length of ducts becomes unmanageable. At this point, it's time to think about a chilled-water system.