HVAC COOLING SYSTEM DESIGN


HVAC COOLING SYSTEM DESIGN
 Cooling and heat dissipation techniques are extremely important topics when it comes to designing and operating a data center. In many instances, system designs fall short of clients’ expectations in terms of reliability and availability. Perhaps naively, often too much importance is placed on the power and network availability without the same being applied to the air conditioning systems.
 Remember, ‘a chain is only as strong as its weakest link’. Infrastructure designs often fail to meet expectations because the same level of reliability/redundancy in many instances is not applied to all other components of the supporting infrastructure. While many people understand that only a short interruption in power supply to computer equipment can mean loss of data, what is often not considered is that an interruption in cooling system can be just as devastating.
This section includes:
1. Heat gains
2. Temperature and humidity requirements
3. Ventilation rates
4. Air quality
5. Cooling loads
6. HVAC equipment


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

6 Temmuz 2018 Cuma

Condenser, Evaporator, and Compressor

Condenser, Evaporator, and Compressor

The condenser is one of three primary elements in your air conditioning system. The other two, the evaporator and compressor, are also important. To understand how the condenser works, it’s important to understand the other two as well.

• Evaporator: The system starts in home with inside air being blown over evaporator coils. These coils contain low-pressure refrigerant which absorbs the heat from the air and converts into a high-pressure gas.
• Compressor: The gas is transferred into the compressor, which is in the outside unit. Here, it’s compressed to help convert it back into a liquid so it can continue the cooling cycle. This produces extra heat.
• Condenser: The condenser is a set of coils, also located inside the outdoor unit. Here, a fan blows across the coils, dissipating the heat from the refrigerant inside them and allowing it to convert back into a liquid, at which point it’s sent back inside to start the process over again.

Without the condenser, the refrigerant would retain its heat and the process would not work. Therefore, it’s important to be able to tell if the condenser is malfunctioning or broken.


Diagnosing Condenser Problems

Often, the problem may not be with the condenser coils themselves, but with the fan or motor in the outdoor unit. The following signs can let you know if the condenser is broken:

• Air conditioner blows warm air inside.
• Outdoor condenser fan doesn’t run.
• Refrigerant leaks from outdoor unit.

What Is the Function of a Compressor in an HVAC System?

What Is the Function of a Compressor in an HVAC System?

The compressor is the heart of the cooling function of heating, ventilation and air conditioning (HVAC) systems. The air conditioner component of a building's HVAC system essentially is a type of refrigerator that cools and dehumidifies the air in the building, ensuring thermal comfort for the occupants. Most HVAC compressors look like a black box with lines running to and from it.

Compressor Function
Air conditioners are devices that transfer heat from an enclosed space to the outside air. The motor-driven compressor in an air conditioning system powers the whole heat-transfer cycle. Air conditioners rely on two facts of nature. One is that heat flows from a high-temperature area to a lower temperature area. The other is that gases always flow from a high-pressure area to a low-pressure area.
Air Conditioning Cycle
The heat-transfer cycle starts as the compressor squeezes the refrigerant. This squeezing action raises its temperature well above that of the surrounding atmosphere. The squeezing action also pressurizes the refrigerant just to its liquefying point so it can flow through the system. The hot, pressurized, liquified refrigerant flows to a condenser coil where it gives up its excess heat to the cooler atmosphere. Typically, a fan blows air through the condenser coil to facilitate transfer of the excess heat.
Expansion Phase
After shedding its excess heat to the atmosphere, the refrigerant flows to an evaporator coil where it expands into a gas at the reduced pressure in the evaporator, which is located in the space to be cooled. This expansion requires heat, which is drawn from the air in the enclosed space that's being cooled. This warms the refrigerant. The cold evaporator also draws humidity from the air. A fan blowing across the evaporator coil facilitates this transfer of heat and humidity. As the compressor pushes hot pressurized refrigerant toward the condenser, it pulls the warm vaporized refrigerant from the evaporator to start the cycle all over again.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40



+90 553 343 50 40

Classification of Valves

Classification of Valves

Fluid control valves are classified in many ways. Following is the classification of valves.


Multi Turn and Quarter Turn Valves

Multi turn valves need many turns of actuator to bring closure member (disc) from fully open position to fully closed position. Examples of multi turn valves are gate valves, globe valves, needle valves, and diaphragm and pinch valves.
While quarter turn valves need only quarter ,0 to 900 degree, motion of closure member (disc) to bring it from full open position to full closed position.  Examples of quarter turn valves are butterfly valves, ball vales and plug valves etc. Quarter turn vales are quickopening valves.

Self actuated Valves

Self actuated valves don’t need actuator to operate them. These valves operate based on some property of fluid line like pressure or flow. Self actuated valves don’t need operator’s interference to control the fluid. Examples of self actuated valves are check valves and pressure relief valves or safety valves.

Linear Motion and Rotary Motion Valves

In linear motion valves, disc moves in linear or straight path to open, close or throttle the flow in valve. While in Rotary motion valves, disc rotates to open, close or throttle the flow. Examples of linear motion valves are gate valves, needle valves, globe valves, diaphragm valves and pinch valves. Examples of Rotary motion valves are ball valves, butterfly valves etc.


General Types of valves

In general following are the types of valves.
• Gate valve
• Globe Valve
• Pinch Valve
• Needle valve
• Diaphragm valve
• Ball valve
• Butterfly Valve
• Check valve
• Pressure relief Valve (safety or relief valve)

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40



+90 553 343 50 40

Electronic Refrigerant Leak Detectors and Methods

Electronic Refrigerant Leak Detectors and Methods
Other methods include portable, hand-held electronic devices, and fixed system monitors. These are recognized as the quickest, cleanest methods.
A question that's commonly asked is, “Are leak detectors helpful in detecting leaks with all of the new refrigerants and R-22 replacement blends?” With the influx of new refrigerants, following the Environmental Protection Agency-mandated phase-out of chlorodifluoremethane (R-22) and other mandates for CFCs, HCFCs and HFCs, detection products and methods continue to be a challenge. With that in mind, many instrument companies have developed and improved their products to meet the current and even future needs with the refrigerant evolution.
Superior Sensing Devices
State-of-the-art leak detectors are able to identify all CFCs, (those containing chlorine), HCFCs (those containing fluorine) and HFCs (non-ozone-depleting refrigerants and compounds), plus bromine gas (found in HBFCs) and halogens. A superior portable leak detection tool will accurately detect and may identify the smallest of leaks. The ability to target the gases and the severity of the leak is the key to a great detection device. Reliability, longevity, serviceability, and cost should also be considered, yet initial cost alone may not be the best deciding factor.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

5 Temmuz 2018 Perşembe

How Does HVAC Work?


How Does HVAC Work?
Understanding Heating, Ventilation, and Air Conditioning Systems, Components, and How They Work
Your home’s heating, ventilation and air conditioning (HVAC) system might be one of its largest components, but unless something goes wrong you probably give very little thought to it. However, understanding how a HVAC systems work helps homeowners troubleshoot potential problems and become a more informed homeowner.
Heating
The heating aspect of your home’s HVAC system is carried out by your furnace. Depending on the style of heat distribution in your home, you may either have electric baseboards, a gas forced air furnace, or radiant heat system (also known as a boiler) installed. For our purposes, we’ll focus on gas-powered forced air systems, as they are the most popular system installed in homes today.
All central heating systems consist of a burner, heat exchanger, blower, and a flue. The burner is what engages when the thermostat calls for heat, and it delivers the fuel to your heat exchanger to begin the heating process. The heat exchanger intakes air and turns the fuel and air mixture into heat that will ultimately be sent through your home’s ductwork. The heated air is then transferred to the air distribution system. The blower is part of this distribution system, and is what ultimately moves the heated air through your ductwork and into the various rooms of your home. We’ll discuss the flue in the next section, as it’s a significant part of the ventilation aspect of the HVAC system.
A boiler-based or hydronic heating system works in a similar manner as a gas-powered forced air system, heating water within the boiler for distribution via piping to radiators located in the various rooms of a house, which then give off heat. Electric baseboards or registers contain a heating element that heats up when the thermostat calls for heat. Some have a blower to help distribute the heat, but some simply give off radiant heating.

Ventilation
The ventilation aspect of your home’s HVAC system is comprised of the flue and vent pipes. It might also involve a fresh air intake pipe or vent. The fresh air intake helps to bring the heated air to the correct temperature before it is distributed throughout the house. The flue and vent pipe are responsible for keeping the air in your home safe to breathe. It works by exhausting harmful byproducts of the combustion process, such as carbon monoxide and other noxious fumes, outside the building. The flue will open and close accordingly in order to ensure there is no backup of dangerous exhaust into your home.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

How air conditioning condensers work?


How air conditioning condensers work?

The air conditioner condenser is the system component that removes heat from the system. The condenser is a heat-exchange surface that permits the transfer of heat from the system refrigerant to the air outside. The heat comes from the space that is being cooled and from the heat generated during the compression process. The air outside for residential systems, must be at a lower temperature than the refrigerant to allow heat transfer to occur. This rejection of heat causes the hot vapor refrigerant coming from the compressor to condense. The purpose of the condenser is to condense the refrigerant to a liquid. The temperature at which the refrigerant will condense is called the condenser saturation temperature.

The Condensing Process

The refrigerant leaving the compressor is superheated and well above the saturation temperature, so it must first be cooled before it can condense. The process of removing the superheat from the discharge refrigerant is referred to as desuperheating. The desuperheating process removes superheat and is a sensible heat exchange since it can be measured with a thermometer. Although the temperature is changing, the pressure will remain the same. The purpose of the first process is to reduce the refrigerant to the condenser saturation temperature.
Once the refrigerants temperature drops to its condenser saturation temperature then it will begin to change state. The second process of the condenser is to change the refrigerant from a vapor to a liquid. The refrigerant goes under a latent heat transfer which cannot be measured, when changing from a vapor to a liquid. Since the refrigerant is still warmer then outside it will still continue to give away heat as a liquid. The condenser has condensed the refrigerant.

Subcooling is the third process of the condenser it cools the refrigerant to a temperature below the condenser saturation temperature. One degree of subcooling is one degree below the condenser saturation temperature. Ideal subcooling temperature is about 20 degrees below the saturation temperature. Subcooling gives the system a high-pressure high-temperature liquid to enter the metering device.



www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Function of Condenser


Function of Condenser
In a cooling cycle of a refrigeration system, heat is absorbed by the vapor refrigerant in the evaporator followed by the compression of the refrigerant by the compressor. The high pressure and high temperature state of the vapor refrigerant is then converted to liquid at the cond. It is designed to condense effectively the compressed refrigerant vapor.
There are basically three types of condensing unit depending on how the heat is removed by the condensing medium which is usually water, air or a combination of both.
  • Air-Cooled types are usually used in the residential and small offices applications. They are used in small capacity systems below 20 tons. The advantages of using this design include not having to do water piping, not necessary to have water disposal system, saving in water costs and not much scaling problems caused by the mineral content of the water. It is also easier to install and has lower initial cost. There isn't much maintenance problems. The disadvantages are that it requires higher power per ton of refrigeration, has shorter compressor life and on days when most cooling is required, the least is available. 

  • The circulation of air-cooled type can be by natural convection or by forced convection (usually using blower or fan). Due to its limited capacity, natural convection is used in smaller applications such as freezers and refrigerators. In forced convection, air is circulated by using a fan or blower that pulls the atmospheric air through the finned coils. Internally, the refrigerant circulates through the coil and air flows across the outside of the tubes.
  • Water-Cooled There are 3 types commonly being used. They are shell and tube, shell and coil, and double tube. The most commonly used is the shell and tube type and are usually available from two tons up to couple of hundred tons. This design has lower power requirements per ton of refrigeration and the compressors can last longer compared to the air-cooled type. A water cooling tower is frequently used for higher capacity application.
  • Evaporative type which is a combination of water and air-cooled.
Air-Cooled and Water-Cooled Comparison Summary
  • Air-cooled type operates at higher head pressure or condensing pressure, hence reducing the capacity of the compressor and increases the power intake. In general, a 2 hp water-cooled system will require the same refrigeration as a 3 hp air-cooled system.
  • The maintenance costs of water-cooled type is about three to four times the air-cooled type. Air-cooled type maintenance is usually limited to regular lubrication of fan and motor bearings. Water-cooled type requires cleaning from algae and bacteria. Scales on the tubes are removed by using acid compound. Proper water treatment is also critical to the operation of the cond.
www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

4 Temmuz 2018 Çarşamba

Types of Filter

Types of Filter
There are basically two types in used today.
• Liquid Line Type
• Suction Line Type

Liquid Line Type is placed after the condenser coil and before the expansion valve. The liquid refrigerant that flows from the condenser to the expansion valve is filtered from particles and moisture before entering it. Good filter will filter out particles that are 20 micron or above from the system.
Some higher end device has sight glass that enables the technician to look into it to see the level of refrigerant. Some have chemical in it that indicate the amount of moisture in the system based on the color of it.
Suction Line Type is placed after the evaporator and before the compressor. This device is used to protect the compressor especially after any failure that contaminates the system.
Motor failure in the compressor usually cause acid and other contaminants to be introduced into the refrigerant system hence it is important to have the suction line filter dryer installed.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Expansion Valves


Expansion Valves
Expansion valves are devices used to control the refrigerant flow in a refrigeration system. They help to facilitate the change of higher pressure of liquid refrigerant in the condensing unit to lower pressure gas refrigerant in the evaporator.
The term "low side" is used to indicate the part of the system that operates under low pressure, in this case the evaporator. The "high side" is used to indicate the part of the system that operates under high pressure, in this case the condenser.
Types of Expansion Valves
There are basically four types of valves that are in used. These valves are also refer to as metering devices.
  • Automatic Exp. Valves
  • Thermostatic Exp. Valves
  • Capillary Tubes
  • Float Valves
Automatic Expansion Valve regulates the flow of refrigerant from the liquid line to the evaporator by using a pressure-actuated diaphragm. It maintains a constant pressure in the evaporator.
The setback is that it is not efficient if the load fluctuates hence this type is not suitable for use in air conditioning as the load fluctuates a lot during its operation.
Thermostatic Expansion Valve uses a valve mechanism to control the flow of liquid refrigerant into the evaporator coil. The flow is controlled by the pressure in the evaporator.
This type of metering device is able to operate well when the load fluctuates and hence is suitable for use in air conditioning system. When the evaporator warms, the valve provides a higher flow rate amd when it cools, it reduces the flow rate.
It is also commonly refer to as TXV, TEV or TX valve. There is a sensing bulb which detects the temperature of the coil and is usually located at a higher temperature within the evaporator.
The bulb must be clamped firmly to the coil to ensure proper sensing. When the temperature of the evaporator increases due to the demand for cooling, the pressure in the bulb will also increase hence pushing the spring to open the valve.
Similarly, when the temperature of the evaporator reduces due to a lack of demand for cooling, the pressure in the bulb will drop hence causing the spring to close the valve.
Capillary Tube is a tube with small internal diameter and could be coiled for part of its length. It is installed to the suction line. A filter-drier is sometimes fitted before the tube to remove dirt or moisture from the refrigerant.
This device is simple, does not have any moving part and lasts longer. In order to use this device, the amount of refrigerant in the system must be properly calibrated at factory level.

Due to its lower cost compared to TXV, this metering device is used in units that are produced in large quantity such as room or window air conditioners.
Depending on the capacity design of the system, the capillary tube internal diameter that is commonly used range from 0.031" to 0.065" and the outer diameter from 0.083" to 0.130".

Float Valve is actuated by a float that is immersed in the liquid refrigerant. Both low-side float and high side-float are used to control the flow of liquid refrigerant.
The low-side float helps to maintain a constant level of liquid refrigerant in the evaporator. It opens when there is no liquid in the evap. and closes when there is liquid in the evap.

The high-side float is located at the high pressure side of the system and maintain a constant level of refrigerant in the condenser. When the compressor operates, the condensed refrigerant flows to the float chamber and opens the valve.
This causes the refrigerant to flow into the evaporator where it is stored. As the liquid level falls in the float chamber, the valve opening will close hence preventing the liquid from flowing to the evap.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

EVAPORATOR COIL

EVAPORATOR COIL
An evaporator coil is the part of an air conditioner or heat pump that absorbs the heat from the air in your house. It is located inside the air handler or attached to the furnace.
How the evaporator and condenser coils work together
The evaporator and condenser coils inside a central air conditioner or heat pump make it possible for these systems to complete the heat exchange process, which is the basis of refrigerated cooling and, in the case of heat pumps, heating. The coils form a loop and, even though they’re continuous, each has a different function.
The role of the evaporator coil
Located inside the blower compartment or air handler, the evaporator coil holds the chilled refrigerant that the compressor moves into it.
As the air from the blower fan moves over the coil, the cold refrigerant removes the heat from your home’s air. The refrigerant becomes warmer and travels to the condenser coil outdoors.
With a heat pump, the process reverses in the winter and the evaporator coil expels heat from the refrigerant into your home, instead of absorbing it and taking it outdoors. Most heat pumps have auxiliary heating elements that are part of the evaporator coil components to supply heat when temperatures fall below a certain point.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Different Types of Fans Used in the HVAC Industry

Different Types of Fans Used in the HVAC Industry

In the Middle East, commercial and industrial units are steadily growing and the demand for HVAC products in the area is remains high. To be able to supply the needs of different industries, many HVAC companies make sure that they deliver high quality products, and one of the most important HVAC products are the different types of fans used. In HVAC equipment, there are different types of fans that are used.

 HVAC FAN TYPES 
All types of fans are designed for the sole purpose of delivering air. In an HVAC unit, most furnaces contain one or more fans, and different fans are used for different applications. There are three basic fan types that are usually encountered in the HVAC industry. The Axial Fan, the Forward Curved Centrifugal Fan and lastly, the Backward Inclined Fan.

Axial Fan
Axial fans, also known as propeller fans, are engineered to move a low volume of air under low static conditions (static pressure is the resistance to air flow). These types of fans are low cost, and don’t work well when it faces resistance. Since propeller fans are low cost, most are built to run on Single Phase Voltages. These types of fans are more suited for applications with lower air volumes and pressures.

Axial fans can usually be found positioned on top of an HVAC Rooftop or home compressor that is outside a house. A basic HVAC system which doesn’t run a heat pump is designed with condenser coils which remove heat from an area. These coils have fins that need air to move through them so as to remove heat. Since these sections don’t require a high power fan, an axial fan is the best and most cost efficient solution.

Centrifugal Fan
Centrifugal fans look similar to hamster exercise wheels. These types of fans produce more pressure for a given air volume than axial fans. They are usually noisier as compared to axial fans and are suited for applications with higher air flow volumes and pressures. It has 3 types of drive mechanism: direct, belt, or variable drive. Inside the HVAC Rooftop system, you will find a centrifugal fan. These fans should be strong enough to overcome all the resistance of the room’s duct-work. This is where axial fans are inadequate. Centrifugal fans move a large quantity of air while overcoming all the resistance or static pressure of the duct-work so that it can provide adequate air flow throughout the facility.

Backward Inclined Fans
These types of fans are designed to handle large volumes of clean air as needed in heating, ventilating, and air conditioning systems. These are also used in many industrial air supply and exhaust applications. There are some HVAC Rooftop units and HVAC accessories that may contain one or a series of backward inclined fans.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40



+90 553 343 50 40

Copper Tubes


Copper Tubes
Copper tube is one of the components that is needed in air conditioning and refrigerant system. The tube is used as a path for the refrigerant to flow between system components and to contain it from escaping to the atmosphere. Sizing, installation layout and fittings must be done properly to ensure that the system runs efficiently.
During installation, it is of utmost importance that moisture, dirt and other contaminants are prevented from entering the system. These foreign particles will affect the performance of the system and may even cause damage to some of the components.
During the production of the copper tube, the inside of the tube has been cleaned and dried before being sealed at both ends to ensure that it remains that way. You must check to make sure that the refrigerant that is going to be used does not react with the copper. Ammonia refrigerant will react with copper hence it should not be used. Instead, the stainless steel tubing type will have to be used.

Types Of Tubing
There are basically two types of tube namely the hard-drawn and the soft type.

Hard-Drawn Copper
This type of tubing is rigid, hard and stiff. It is not easily bent and should not be bent. Fittings are used to obtain the configuration needed for the installation. The length commonly available is 10 feet or 20 feet. There are three standard weight with different wall thickness for each type. Type K has the thickest wall tubing followed by Type L and Type M. If you need a higher pressure tube, thicker type is to be used to ensure it can handle the pressure of the refrigerant. Type L outer diameters typically starts from 3/8 inch followed by 1/2 inch, 5/8 inch, 3/4 inch, 7/8 inch, 11⁄8 inch, 13⁄8 inch, 15⁄8 inch, 21⁄8 inch and 25⁄8 inch.

Soft Copper 
The soft copper is flexible and comes in rolls of 25 feet or 50 feet. The typical outer diameter ranges from 1/8 inch to 13⁄8 inch. Markings of ACR are done on the tubing to indicate that it is used for air conditioning and refrigeration purposes. During production, these parts are cleaned and dehydrated to remove the moisture from the tube. It is then filled with nitrogen gas before being capped.
Insulation & Pre-caution 
In order to prevent the refrigerant from absorbing unnecessary heat from the ambient, the copper tube is insulated between the evaporator and the compressor at the low pressure side of the system. Hence you will be able to see the insulation material being wrapped around the copper tubes for this purpose. It is also to prevent condensation from happening on the tubes.
When cutting the tubing to the required length, make sure that you use a proper tool such as the tube cutter.The burr on the inside of the tube that resulted from the cutting must be removed from the tube as these contaminants will affect the flow of refrigerant as well as affecting the performance of the system.
When bending is required, take note that only the soft copper type can be bent. Use a proper tube bending springs to prevent flatten or kink.
When soldering or brazing is required, make sure that you have being trained to do this and adhere strictly to the instructions of the manufacturers.
Wear eye protection when particles are being released in the air as a result of your action.
When you are doing annealing process where you heat up the tube and allow it to cool slowly, make sure that you use a flared flame over a distance of 1 feet at a time and not concentrating the heat on one location.
Ensure the work place is well ventilated especially when fumes is being emitted as a result of your work. Do not breathe in excessive gas and adhesive.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40


+90 553 343 50 40

Chilled-water and Cooling-tower AC Units

Chilled-water and Cooling-tower AC Units
Although standard air conditioners are very popular, they can use a lot of energy and generate quite a bit of heat. For large installations like office buildings, air handling and conditioning is sometimes managed a little differently.
Some systems use water as part of the cooling process. The two most well-known are chilled water systems and cooling tower air conditioners.
• Chilled water systems - In a chilled-water system, the entire air conditioner is installed on the roof or behind the building. It cools water to between 40 and 45 degrees Fahrenheit (4.4 and 7.2 degrees Celsius). The chilled water is then piped throughout the building and connected to air handlers. This can be a versatile system where the water pipes work like the evaporator coils in a standard air conditioner. If it's well-insulated, there's no practical distance limitation to the length of a chilled-water pipe.
• Cooling tower technology - In all of the air conditioning systems we've described so far, air is used to dissipate heat from the compressor coils. In some large systems, a cooling tower is used instead. The tower creates a stream of cold water that runs through a heat exchanger, cooling the hot condenser coils. The tower blows air through a stream of water causing some of it to evaporate, and the evaporation cools the water stream. One of the disadvantages of this type of system is that water has to be added regularly to make up for liquid lost through evaporation. The actual amount of cooling that an air conditioning system gets from a cooling tower depends on the relative humidity of the air and the barometric pressure.
Because of rising electrical costs and environmental concerns, some other air cooling methods are being explored, too. One is off-peak or ice-cooling technology. An off-peak cooling system uses ice frozen during the evening hours to chill interior air during the hottest part of the day. Although the system does use energy, the largest energy drain is when community demand for power is at its lowest. Energy is less expensive during off-peak hours, and the lowered consumption during peak times eases the demand on the power grid.

Another option is geo-thermal heating. It varies, but at around 6 feet (1.8 meters) underground, the earth's temperature ranges from 45 to 75 degrees Fahrenheit (7.2 to 23.8 degrees Celsius). The basic idea behind geo-thermal cooling is to use this constant temperature as a heat or cold source instead of using electricity to generate heat or cold. The most common type of geo-thermal unit for the home is a closed-loop system. Polyethylene pipes filled with a liquid mixture are buried underground. During the winter, the fluid collects heat from the earth and carries it through the system and into the building. During the summer, the system reverses itself to cool the building by pulling heat through the pipes to deposit it underground
For real energy efficiency, solar powered air conditioners are also making their debut. There may still be some kinks to work out, but around 5 percent of all electricity consumed in the U.S. is used to power air conditioning of one type or another, so there's a big market for energy-friendly air conditioning options

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Basic Types of Check Valves

Basic Types of Check Valves

It is very important for HVAC mechanical engineer to know about various valves being used in mechanical industry.Various check valve types have been developed to cater to the diversified requirements in piping systems in various applications.These various types of check valves offer many advantages and disadvantages .One type of check valve ideal for one applicationmay be misfit for another application.Plant engineers have to look into many factors to decide which type of valve would be they using in that particular application.


Following are the main check valve types used in various applications.

1. Swing Check Valve
2. Tilting Disk Check Valves
3. Lift Check Valves
4. Piston Check Valves
5. Butterfly Check Valves
6. Stop Check Valves
7. Other Check valve types (Ball check valve, diaphragm check valve etc)


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

Why we use Check Valves or Non-Return Valves or one way valves?

Why we use Check Valves or Non-Return Valves or one way valves?

Sometimes reverse flow may be detrimental for equipment or process so it needs to be uni-directional for operational safety. This operational safety is accomplished by valve check. Valves check are self actuated and self operating devices.
• Check   Valves   are used to protect the equipment that can be affected by reverse flow, such as flow meters, strainers and flow control valves.
• Check   Valves   are used to check the pressure surges associated with hydraulic forces, for example, water hammer
• Check Valves   are used to prevent the flooding that can take place if flow reversed.
• Check Valves   are used to prevent the reverse flow on system shutdown.
• Check Valves   are used to to prevent the flow under gravity.
• Check Valves   are used for relief of vacuum conditions.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

What is a Check Valve or Non-return valve (NRV)?

What is a Check Valve or Non-return valve (NRV)?

Check valves or non-return valves are self actuated valves and designed to prevent the reversal of flow in a piping system. In other words we can say that Check valves are basically backflow preventers. Valve Check continues to work even if plant loses it power,air supply or hydraulic power source. Even these flow preventers or one way valves do not need operators assistance to function.

How Does  a Check valve Work?

Check valves are activated by the flowing material in the pipeline.This flowing material may be gas,water ,air ,oil or steam in pipeline. The pressure of the fluid passing through the system opens the check valve, while any reversal of flow will close the valve.Opening of valve is basically lifting or swinging of check valve disc thus allowing the flow in one direction.Closure in check valve, for backflow prevention, is accomplished by the weight of the check mechanism, by back pressure, by a spring, or by a combination of these means.

www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40



+90 553 343 50 40

Basic Principles of Air Conditioning

Basic Principles of Air Conditioning
You don’t have to be an air-conditioning expert to use Bilkar Coolers, but understanding the basics of air conditioning will help you understand how Bilkar Coolers work.
This section highlights some of the basic principles of air conditioning for those who would benefit from additional knowledge in this area.
PRINCIPLES OF COOLING
Heat Transfer
Heat is a form of energy. Every object on earth has some heat energy. The less heat an object has, the colder we say it is. Cooling is the process of transferring heat from one object to another. When an air-conditioning system cools, it is actually removing heat and transferring it somewhere else. This can be demonstrated by turning on a Spot Cooler and placing one hand in front of the cold air nozzle and the other over the warm air exhaust. You will feel the action of the transfer of heat.
SENSIBLE AND LATENT HEAT
There are two forms of heat energy: sensible heat and latent heat.
Sensible heat is the form of heat energy which is most commonly understood because it is sensed by touch or measured directly with a thermometer. When weather reporters say it will be 90 degrees, they are referring to sensible heat.
Latent heat cannot be sensed by touch or measured with a thermometer. Latent heat causes an object to change its properties. For example, when enough latent heat is removed from water vapor (steam or humidity), it condenses into water (liquid).
If enough latent heat is removed from water (liquid), it will eventually freeze. This process is reversed when latent heat is added.

CHANGE OF STATE
An object that changes from a solid to a liquid or liquid to vapor is referred to as a change of state. When an object changes state, it transfers heat rapidly.
HUMIDITY
Moisture in the air is called humidity. The ability of air to hold moisture directly relates to its temperature.
The warmer air is, the more moisture it is capable of holding. Relative humidity is the percentage of moisture in the air compared to the amount of moisture it can hold. A moisture content of 70°F air with 50% relative humidity is lower than 80°F air with 50% relative humidity.
When the humidity is low, sweat evaporates from your body more quickly. This allows you to cool off faster. High humidity conditions do not allow sweat to evaporate as well because the air is at its maximum capacity.
Humidity is also a form of latent heat. When air contains more humidity, it has more latent heat.


www.bilkargroup.com
www.bilkarsogutma.com.tr
info@bilkargroup.com
+90 212 343 50 40
+90 553 343 50 40

What Is Considered the Air Flow of an Axial Fan?

What Is Considered the Air Flow of an Axial Fan?
Airflow is measured in cubic meters per hour and describes the expected amount of air that will flow through the fan in one hour’s time. In complex systems, there may be many fans working together to get a desired airflow. Axial fans can also be installed in different locations and set up so that airflow is directed smoothly through a space, or so that the space has positive or negative pressure due to the working of the fans.


What Is the Fan Speed?
Fan speed is measured in rpms and describes the speed at which the propeller rotates. This is variable on many models fans and, in fact, the axial fans used in computers are designed to be variable speed to cut down on a nuisance factor of high rpms: noise.

Fan speeds tend to be directly related to fan size. Larger fans move more air and, because of that, they can oftentimes be run at lower rpms than smaller fans to move the same quantity of air. For applications where a user is going to be next to a machine that requires fan cooling, putting larger fans in the device sometimes allows for proper cooling with less noise than smaller fans would generate.

What Is Considered AC or DC Operation of an Axial Fan?
This simply indicates whether the fan runs on AC or DC power.

What Does the Direction of Curve Define?
The direction of the blades in relation to the rotation of the fan is described as the curve. In a forward curved fan, for instance, the blades are oriented in the same direction as the rotation of the fan. In some cases, very engineered systems may require a specific curve direction for the fan. This may not be much of a factor in less demanding applications, however.


What Is the Power Consumption of an Axial Fan?
The power consumption of an axial fan is one of its most desirable features. This describes the amount of power required to run the device in watts. Axial fans are enormously efficient to operate.

How Is the Noise level of an Axial Fan Defined?
All fans make some noise. This is measured in decibels (dB) and expresses the amount of noise the fan generates during normal operation. This is a concern where both large and small fans are being installed. Small fans rotating at high rpms can generate a great deal of noise, for instance, a problem for powerful computers that require a great degree of thermal management. Larger fans can also generate a great deal of noise, in some cases. Poorly engineered fans may have problems with vibration, which can increase the amount of noise they generate.

Which Sensor Output Types Exist for Axial Fans?
Sensor outputs on fans are important in applications where flow has to be precisely controlled, such as in computer cases. Fans are outfitted with many different types of sensors, including tachometers, voltage outputs, temperature outputs, open collectors, which provide rpm data.
Some fans can be very precisely controlled via software. Computer fans can usually have their speeds set manually by the user, which some programmers and other demanding users take advantage of to make sure their computer is being cooled as much as possible at all times.

Which Blade Diameters Are Available for Axial Fans?
Blade diameters range from a few millimetres and up. It is simply the diameter of the propeller element of the fan